Electrical and Systems

RV and Fleet Generator Service, Repair and Replacement

Typical range

$400 to $8,500+

Shop hours

2 to 35+

Labor rate

$260/hr

The short answer

Generator service covers scheduled maintenance, no-start and no-output diagnosis, carburetor and fuel system work, and full replacement on Onan and Cummins units. Work runs $400 to $8,500 and up, or 2 to 35 plus hours at $260 per hour plus parts.

01

What this work actually involves

Most generator failures we see are not mechanical wear. They are storage failures. A coach that sits eleven months a year in Yorba Linda, Corona, or Riverside gums its carburetor jets with varnished ethanol fuel, and then the owner cranks it flat trying to start it before a trip. Gasoline Onan units are the worst offenders because the jets are small and the float bowl sits low. Diesel units fail differently, usually air in the fuel line or an injector that has sat dry, but the root cause is the same lack of exercise under load.

The second failure category is heat and load. A generator mounted in a sealed compartment on a coach parked in Indio or Palm Desert is drawing 120 degree intake air before it even starts working. Run two air conditioners off it at that ambient and it will overheat, drop output voltage, and eventually trip its own thermal protection. Owners read low voltage at the outlets as an electrical fault in the coach when the generator is simply running out of margin.

The third is output rather than running. A unit that starts and runs beautifully but produces no 120V usually has a failed voltage regulator, worn brushes, or an open winding, and that is a completely separate repair path from a fuel problem. We test output under a real load bank rather than plugging in a light and calling it good, because a generator can make voltage at no load and collapse at 20 amps.

Systems and brands we work on: Onan, Cummins.

Location: All work is performed at our Yorba Linda facility. We do not offer mobile, roadside, or fleet route service.

02

What the job includes

  • Scheduled service including oil, filters, plugs, and air cleaner
  • No-start diagnosis covering fuel, spark, compression, and control board
  • Carburetor removal, cleaning, rebuild, or replacement on gasoline units
  • Diesel fuel system bleeding, filter service, and injector diagnosis
  • Voltage regulator, brush, and stator testing on no-output complaints
  • Load bank testing of real output at rated amperage
  • Start and stop control circuit, remote panel, and wiring repair
  • Exhaust system, muffler, and mounting repair or replacement
  • Compartment ventilation and intake air path correction
  • Full generator replacement and commissioning

03

When you need this service

  • Cranks strongly but will not fire after months in storage
  • Starts and then dies within thirty seconds under any load
  • Runs fine but delivers no 120V at the coach outlets
  • Output voltage sags and air conditioners short cycle on hot days
  • Surging or hunting engine speed that will not settle
  • Black smoke, a fuel smell, or exhaust entering the coach
  • Repeated shutdowns on its own thermal or overload protection

04

How we do it, step by step

  1. 01

    Reproduce the failure

    We run the unit and watch it fail rather than working from the description. No-start, no-output, and shutdown-under-load are three different repairs and they get confused constantly.

  2. 02

    Fuel and ignition path

    On a no-start we verify fuel delivery at the carburetor or injection pump, spark or injection event, and compression before touching the control board.

  3. 03

    Electrical output testing

    On a no-output complaint we test the voltage regulator, brushes, and stator windings, then load bank the unit at rated amperage to see whether output holds.

  4. 04

    Thermal and ventilation check

    Compartment intake and exhaust path measured. A generator pulling recirculated hot air will never make rated output in low desert conditions no matter what we replace.

  5. 05

    Documented findings and pricing

    Photographed findings with measured numbers and a repair-versus-replace comparison, because on older gasoline units a rebuild sometimes exceeds the value of the set.

  6. 06

    Repair and load verification

    Parts installed, service intervals reset, and the unit run under load bank at rated output for a sustained period before we call it finished.

05

Pricing and posted rates

Pricing for Generator Service and Repair
ItemRate or rangeNotes
Typical job range$400 to $8,500+Varies with extent of damage and parts availability
Shop hours2 to 35+Quoted after teardown, not before
Mechanical and electrical labor$260 per hour2026 posted rate
Parts100% markup under $100, 35% overSpecial order parts require a non refundable deposit at order
Deposit50% at authorization over $2,000Additional 25% when parts arrive on jobs over $10,000
Sales tax7.75% on parts and materialsLabor is not taxed

Insurance billed jobs may be billed at carrier negotiated labor rates that differ from the posted retail rates above. See all posted rates.

07

Vehicles we do this work on

08

Questions about generator service and repair

Frequently asked questions

How much does RV generator repair cost?

Work runs $400 to $8,500 and up, or 2 to 35 plus hours at $260 per hour plus parts. A service with a carburetor clean on an accessible gasoline set is at the low end. A full diesel generator replacement with new mounts, exhaust, wiring, and commissioning is at the high end.

My generator will not start after sitting all winter. What is wrong?

Nine times out of ten it is varnished fuel in the carburetor jets on a gasoline unit, or air and stale fuel in the lines on a diesel. Ethanol blended pump gas separates and gums within a few months. The fix is a carburetor clean or rebuild and fresh fuel, and the prevention is running it under load monthly.

It runs but I get no power in the coach. Is that the generator?

It could be the generator output side or it could be the transfer switch. A generator that runs and makes no voltage usually has a failed regulator, worn brushes, or an open winding. A generator making good voltage that never reaches the coach is a transfer switch problem. We test at the generator terminals first to split the two.

How often should I service my generator?

Follow the hour interval in the manual, but the more important habit is running it under at least half load for a couple of hours every month. Generators fail from sitting, not from running. Exercising it circulates oil, keeps the carburetor wet, and surfaces a problem in your driveway instead of at a campground.

Do you replace generators as well as repair them?

Yes. Full replacement including mounts, exhaust, fuel connections, control wiring, and commissioning is done in the shop. On older gasoline sets where parts availability is poor, we price the rebuild against the replacement so you can compare real numbers rather than guessing.

09

Related services

10

More electrical and systems work

Ready to move on generator service and repair? Bring it to Yorba Linda.